JP

|

EN

Urine Aliquot System

IDS-Hr2

With a compact footprint of just 0.935 m², the IDS-CLAS Hr2 is a smart and space-efficient urine aliquot system engineered to standardize and automate the preparation of urine samples for both automated chemistry and sediment analysis.

Designed for laboratories seeking predictable turnaround times while minimizing direct operator exposure and manual handling, the IDS-Hr2 transforms urine processing into a controlled, traceable, and reproducible workflow.

The system intelligently selects between two secondary tube types, automatically preparing the correct tube type based on test requirements.

Each aliquot tube is precisely labeled and sorted onto the appropriate rack, ensuring accurate routing/transfer to its designated analyzer.

This streamlined preparation process reduces pre-analytical bottlenecks, errors and enables laboratories to move samples directly into testing with greater efficiency and confidence.

Whether deployed as a standalone workcell or integrated into a Total Laboratory Automation line, the IDS-CLAS Hr2 supports modular expansion and parallel configuration, allowing laboratories to increase throughput or introduce operational redundancy as testing demand grows. 


The IDS-Hr2 is a smart and compact urine aliquotting system designed to automate the preparation of urine samples for both automated chemistry and sediment analysis.

By aliquoting urine directly from the patient’s collection cup, IDS-Hr2 has the mechanism to ensures accurate volume distribution, test-specific tube labeling, and efficient sample sorting.

Prior to aliquoting, automated mixing ensures sample homogeneity by minimizing sedimentation and concentration variability to support consistent, reproducible test results.

This enables laboratories to immediately transfer the prepared aliquotted samples to their respective analyzers for on-the-spot testing and analysis.

The IDS-Hr2 seamlessly integrates with the IDS Sample Transport System, enabling full automation of sample transfer to designated urine analyzers without any manual handling.

*Contact our sales representative to check if this product is available in your country/region.

1
01. Urine Cup Inlet/Outlet Extension

With the capacity extension, the module accommodates more collection cups and facilitates the streamlined handling of completed samples for downstream analysis.

✅ Detects insufficient urine volume and alerts operators right away.

2
2. Urine Cup Loading Area (Main)
  • Urine Cup is Loaded.
  • Barcode is read to confirm arrival.
  • Detects insufficient urine volume and alerts operators right away.

3
3. Secondary Tube & Labeling 
  • Depending on the test ordered specified tubes are fed to the labeling area.
  • Prints barcode label and applies to each aliquot tube.

  •  
4
4. Cup Transfer

Discharges error or completed samples* to extended unit (if available). and notifies the operator with a melody

*Completed samples are kept, depending on sample disposal instructions.

5
4. Aspirating and Aliquoting

Urine Sample from collection cup is aliquotted to either round bottom (for chemistry analysis) or conical-shaped (for sediment analysis) tubes, depending on test ordered.

  • Features IDS unique aliquot tip with an aspirating volume of 22ml. Enabling multiple aliquots from a single draw, minimizing delays in processing time.
  • New disposable aliquot tips are fed for every sample

6
07. Urine Cup Auto-Disposal Area (At the back of the Processor. Not visible)

Completed collection cups are disposed separately from urine sample.

Urine sample drained into an internal tank and cups are disposed separately.

7
08. Outlet (for aliquot tubes)

Unloading and sorting of aliquot tubes on respective personality racks

8

8. Disposable Pipette Tip Feeder

Loading new disposal tips as needed without interrupting system operations

9

10. Conical-Bottom Tube Feeder

The system also features a single pull-out drawer containing dual independent supply channels that allows simultaneous loading of two different conical-bottom tube types.

10
09. Touch-Screen Control Monitor

Intuitive User Interface which requires less time to learn how to operate.

Product design and specifications are subject to change without notice.

1. Urine Collection Cup is placed on the loading plate and barcode is read to confirm sample arrival.

2. Test-specific secondary tubes are supplied and labels traceable to primary sample are applied.

3. Urine samples is aspirated from the primary cup and dispensed using a 22 mL disposable tip.

4. After aliquoting, the primary cup exits the queue and the operator is notified.

5. Aliquoted tubes are sorted in respective analyzer racks.

6. IDS-CLAS X-1 track system can be integrated to enable fully automated transport to connected analyzers.

7. Residual urine and cups are discarded per laboratory instructions.

8. Optional unit enables automated cup loading or unloading.

Module Dimensions 

  • 1,100 mm (W) x 850 mm (D) x 1,500 mm (H) (Main unit)
  • 1,720 mm (W) x 850 mm (D) x 1,500 mm (H) (Including urine cup aliquoting expansion unit)

Module Weight 

400 kg or 881.8 lbs


General Power supply 

  • AC100V 1φ 50/60Hz 3A (main body)
  • AC100V 1φ 50/60Hz 6A (LC)

Bar code labeling format 

  • Barcode Type
    • Choice of NW-7, ITF, CODE39, CODE128
  • Barcode Digit Number
    • Maximum 15 digits (including sub-specimen number)

Urine Collection Cup Type

IDS Collection Cup


Secondary Aliquot Tube

Supports Two Tube Types –

  • Conical Bottom Test Tube – For Urine Sediment Analysis
  • Round Bottom Test Tube – For Urine Chemistry Analysis

Aliquot/Dispensing tip 

Maximum Vol of 22,000μL (22ml) tip using IDS dedicated aliquot tip 


Urine Mixing Function

Whirlpool mixing mechanism


Aliquoting precision 

Within 5% of requested amount, CV within 10% (when dispensing 1.0mL)


Aliquot processing speed or Throughput

  • Maximum 180 samples/hour (1:1 dispensing volume = 5mL)
  • Maximum 150 samples/hour or more (1:2 dispensing volume = 5mL)

STAT priority loading 

Up to 10 sample tubes in one rack is possible 


Specimen loading capacity (Standard Specification) 

Collection Cup Loading Plate :10 cups

Aliquot tube Unloading :80 tubes (Determined by the specification.)


Specimen loading capacity (Extension Specification) 

Collection Cup Loading Plate : +28 cups


Sorting & Unloading Capacity

Aliquot tubes: Yes 

Maximum capacity of 70 (7 racks × 10 samples/rack)


 

Open Automation
Solution

IDS track-based automation systems are designed for open connectivity and have been successfully integrated with over 100 analyzers across 40+ leading IVD manufacturers.
Our systems support multi-disciplinary testing environments as seen below.

Established Analyzer
0 +
IVD manufacturers
0 +

Analyzer Connection Types :

Rack-based transfer

Tube-based transfer

Outboard Sampling

Custom connections

Multi-disciplinary

Chemistry

Immunoassay

Coagulation

Urine Analysis

Hb A1c

Hematology

Molecular

Benefits

Open Connectivity

Integrate freely across multiple IVD disciplines and analyzers.

Flexible Integration

Adapt to any laboratory layout or operational flow.

Scalable Modules

Grow your automation system as your lab’s needs evolve.

Future-Proof System

Designed with upgrade paths and continuous innovation in mind.

Our clients love working with us, just read what they have to say!

Get in Touch with Us

Download Brochure

Are you a healthcare professional?

This page contains information about our products for medical professionals. 

Please note that it is not intended to provide information to the general public