Automated Aliquot System

IDS-CLAS 2800

The IDS-CLAS 2800 standardizes sample preparation to help laboratories maintain predictable turnaround times while reducing manual handling, variability, labeling risk, workflow congestion.

As a standalone unit, the system processes sample preparation from sample reception through decapping, aliquoting, and pre-analytical sorting. Samples can be aliquoted into up to four different secondary tube types, supporting parallel testing workflows across multiple analyzers and handles up to 15 aliquots per sample.

Additional modules such as centrifugation before aliquoting or recapping after dispensing can be added to support laboratory-specific workflow requirements.

Product availability, features, and configuration options may vary by region and can be tailored to meet local market needs and regulatory requirements.

1. Increased Productivity

Throughput of up to 320 samples/hour, supporting faster turnaround times.

2. Compact, Space-Efficient Design

1.33 m² footprint integrating sample reception to advanced sorting.

3. Tube Type Characterization

Vision-guided tube and cap recognition confirms samples against test orders.

4. Standardized Sample

Aliquoting up to four secondary tube types.

1
1. Primary Tube Loading & Unloading Area

Routine samples are loaded from IDS 50-tube rack onto system track where sample barcodes are scanned to confirm receipt and routing. Samples with barcode error are placed into the adjacent error rack (1 x 10-tube rack). STAT samples can be prioritized on a configurable 5 x 10-tube rack.

Processed primary samples can be unloaded back to the same 50-tube rack.

2
2. STAT & Routine Sample Loading + Error Sample Unloading Area

When urgent samples are loaded on the configured STAT sample rack, the loading arm will pick up the STAT Sample before going over to pick up the routine samples. 5x 10-tube rack which are configurable to be routine or STAT samples.

Samples with labelling or identification issues are loaded back into the 1x 10-tube rack that is next to the 50-tube rack is error sample rack.

Barcodes are scanned to confirm receipt and routing.

3
3. Blood Clot Detection Area

The interface between the serum and the separating agent in the sample is scanned and this data is used during aliquoting.

4
4. Decapping Area

Removes the following tube closures including :

  • Rubber
  • Plastic
  • Screw

Samples with caps that cannot be removed are sent to the error rack in the primary tube unloading area (1) or (7).

5
5. Secondary Aliquot Tube Labeler

The system allows up to 4 aliquot (secondary) tubes per primary tube to be set up.

Labels are automatically printed and applied to the aliquot tubes depending on the number of test ordered and then gets sent to the aliquoting area.

The automation system can be manufactured with the barcode labeler of your choice, allowing customization to fit your specific operational requirements.

Barcode Labelling format type

  • NW-7
  • ITF
  • CODE39
  • CODE128
6
6. Aliquoting Area

Depending on the volume, up to 15 aliquot (secondary) tubes can be dispensed per primary tube by the system.

Labels are automatically printed and applied to the aliquot tubes depending on the number of test ordered and then gets sent to the aliquoting area.

The automation system can be manufactured with the barcode labeler of your choice, allowing customization to fit your specific operational requirements.

You can choose the Barcode Labelling format type

  • NW-7
  • ITF
  • CODE39
  • CODE128
7
7.Primary Tube Unloading Area

There are 2 x IDS 50-tube rack which are configurable to receive processed Primary tubes and also Aliquot (secondary) Tubes.

 
Efficient Sample Management with Customizable Sorting Features

Easy sample management with advanced sorting capabilities. Sorting groups can be customized in increments of at least 5 samples. Personality racks can be configured to sort samples based on various criteria, including test type, priority, or destination analyzer.

8
8.Secondary Tube Unloading Area/ Personality Racks

Sensored Racks that lights up when racks are ready for next step. Technicians can walk away to work on other priority task and are alerted visually if any specific rack or samples requires manual attention.

  • Blue light - Racks are complete
  • Blue Flickering light - Attention needed
Efficient Sample Management with Customizable Sorting Features

Easy sample management with advanced sorting capabilities. Sorting groups can be customized in increments of at least 5 samples. Personality racks can be configured to sort samples based on various criteria, including test type, priority, or destination analyzer.

9
9.Bulk Loading Area

The IDS-CLAS 2800 is equipped with two distinct supply areas for loading secondary aliquot tubes, offering enhanced flexibility and uninterrupted operation in high-throughput environments. Each supply position accommodates a different tube size or type, allowing operators to load up to four types of secondary tubes (two 75mm and two 100mm) simultaneously.

Accommodates two different φ13×75mm tube types.

10
10.Set-In Loading Area for Secondary Tubes

The IDS-CLAS 2800 is equipped with two distinct supply areas for loading secondary aliquot tubes, offering enhanced flexibility and uninterrupted operation in high-throughput environments.Each supply position accommodates a different tube size or type, allowing operators to load up to four types of secondary tubes (two 75mm and two 100mm) simultaneously.

The set in loading accommodates two different φ16×100mm tube types

11
11.Disposable Pipette Tip Loading Station

Loading new tips as needed, enhancing efficiency and without stopping the system.

12
12. Touch-screen Control Monitor

A system operating PC with intuitive operator interaction. Offers real-time views of system operation and rack sorting.

Product design and specifications are subject to change without notice.

1. Primary tubes are removed from racks and loaded onto system.

2. Barcodes are scanned to confirm receipt and test orders.

3. Optical boundary detection determines the available serum volume.

4. Primary tubes are decapped. Caps are discarded as biohazard waste.

5. Test-specific secondary tubes are supplied and labels traceable to primary sample are applied.

6. Serum or plasma is aspirated and dispensed using disposable tips.

7. Completed aliquots and primary samples are sorted into designated analyzer racks.

Module Dimensions 

1,570mm(W)×850mm(D)×1,500mm(H)
61.8 in. (W) x 33.5 in. (D) x 59.0 in. (H)


Module Weight 

434 kg, or 956.8 lbs.


General Power supply 

Single-phase 100 volts AC 15A (including line controller PC).


Barcode labeling format 

Choice of NW-7, ITF, CODE39, CODE128


Primary Tube

Supports intermixable Tube Types Depending the need of the laboratory – Dimension of 13mm x 75mm, 13mm x 100mm, 16mm x 75mm & 16mm x 100mm


Secondary Aliquot Tube Type

The mechanism of the device can be customized to support the laboratory’s specific needs for secondary tube types.

The system  is designed to accommodate either 13mm or 16mm diameter tubes.


Aliquot tip 

Maximum Vol of 2,000μL tip using IDS dedicated aliquot tip

Aliquoting precision 

Within 3% CV across the entire range. Within 3% CV at 300μL. 


Aliquot processing speed or Throughput

Maximum 320 sample/hour (at 300μL) 


STAT priority loading 

Up to 10 sample tubes in one rack is possible 


 Specimen loading capacity (Standard Specification) 

Primary tube loading :50~100-tube(Determined by the specification.) 
Primary tube Unloading :10~290-tube(Determined by the specification.)

Aliquot tube Unloading :10~290-tube (Determined by the specification.) 
Aliquot tube Error Unloading :20-tube or more (Determined by the specification.) 


Sorting & Unloading functions 

Primary tubes: Yes, Aliquot tubes: Yes 


 

 

Open Automation
Solution

IDS track-based automation systems are designed for open connectivity and have been successfully integrated with over 100 analyzers across 40+ leading IVD manufacturers.
Our systems support multi-disciplinary testing environments as seen below.

Established Analyzer
0 +
IVD manufacturers
0 +

Analyzer Connection Types :

Rack-based transfer

Tube-based transfer

Outboard Sampling

Custom connections

Multi-disciplinary

Our systems support multi-disciplinary testing environments as seen below.

Chemistry

Immunoassay

Coagulation

Urine Analysis

Hb A1c

Hematology

Molecular

Key Features

Open Connectivity

Integrates across multiple IVD disciplines and analyzers.

Flexible Design

Adapt to any laboratory layout or operational flow.

Scalable Modules

Grow your automation system as your lab’s needs evolve.

Future-Proof System

Designed with upgrade paths and continuous innovation in mind.

Get in Touch with Us

Download Brochure